# NACK reasons

> Every NACK reason code by number, the reason a fixture gives when it refuses a request, with what each means at the bench.

- **NACK reasons:** 27
- **Numbered in:** E1.20, Table A-17
- **Version:** 0.12.0
- **Runs on:** macOS 15 Sequoia or later, Apple silicon or Intel
- **Needs:** An Enttec DMX USB Pro with its DMX/RDM firmware (major version 2), or, on a rig, an Art-Net 4 node with RDM on at its ports
- **Price:** Free

A fixture that refuses an RDM request answers with a NACK and a reason code, numbered in [E1.20](https://tsp.esta.org/tsp/documents/published_docs.php)'s Table A-17 and in the standards that extend it. RDMBench's [wire log](/help/wire-log/) shows the reason beside the refusal. Here is every code by number, with what it means at the bench, in RDMBench's words rather than the standard's.

- [`0x0000` NR_UNKNOWN_PID](/codes/nack/0x0000/): The unit does not have this parameter. The most common refusal and usually harmless: a unit lists what it supports, and anything else should get this answer. It is a fault only for a parameter every responder must answer, and some units say nothing at all instead, which reads as a timeout rather than a refusal.
- [`0x0001` NR_FORMAT_ERROR](/codes/nack/0x0001/): The unit heard the request but its data was the wrong length or shape for this parameter. From a well-tested controller it points at the unit's firmware reading the parameter another way, often an older revision of the standard; from a hand-built request, check the data length first.
- [`0x0002` NR_HARDWARE_FAULT](/codes/nack/0x0002/): The unit understood the request, but something inside it kept it from acting. The one refusal about the fixture's hardware rather than the conversation: read its status messages and sensors, and try the same change from its own panel to see whether that fails too.
- [`0x0003` NR_PROXY_REJECT](/codes/nack/0x0003/): Something between the controller and the unit, a node, splitter or proxy that answers RDM for the units behind it, turned the request away, and the unit may never have seen it. Put the unit on a direct line before reading anything into it.
- [`0x0004` NR_WRITE_PROTECT](/codes/nack/0x0004/): The setting can normally be changed, but not right now. At the bench this is usually a lock you can see: a panel or menu lock, a password, or a setting held by the current mode or by a standalone program the unit is running. Unlock it on the fixture and try again.
- [`0x0005` NR_UNSUPPORTED_COMMAND_CLASS](/codes/nack/0x0005/): The unit has this parameter, but not for this kind of request: most often one that can be read and not set, or set and not read. Not a fault; on some models the setting is changed only from the panel.
- [`0x0006` NR_DATA_OUT_OF_RANGE](/codes/nack/0x0006/): The unit understood the request, but will not take that value: an address past what its footprint leaves, a personality it does not have, a sensor number past its count. Check the value against what the unit itself reports, not the manual, which may be for other firmware.
- [`0x0007` NR_BUFFER_FULL](/codes/nack/0x0007/): The unit's queue was full and it could not take the request. Usually brief: wait and ask again. If it lasts with nothing else on the line, the unit is not emptying its queue, which is its firmware.
- [`0x0008` NR_PACKET_SIZE_UNSUPPORTED](/codes/nack/0x0008/): The request was bigger than the unit can hold. A controller should keep within what the unit takes; on an ordinary request it is the unit's limit, not the cable, and worth a note to the maker.
- [`0x0009` NR_SUB_DEVICE_OUT_OF_RANGE](/codes/nack/0x0009/): The request named a sub-device the unit does not have. Sub-devices are separately addressed parts of one unit, such as the modules of a dimmer rack; most fixtures have none. If the unit's own sub-device count says it has that one, it contradicts itself.
- [`0x000A` NR_PROXY_BUFFER_FULL](/codes/nack/0x000a/): A proxy between the controller and the units has no room left for the replies and status messages it holds for them. The units behind it may be fine: ask more slowly, or take the unit off the proxy.
- [`0x000B` NR_ACTION_NOT_SUPPORTED](/codes/nack/0x000b/): The value was acceptable, but the unit cannot make the change as it is set up now. Look for another setting that has to change first, such as a mode the requested one depends on.
- [`0x000C` NR_ENDPOINT_NUMBER_INVALID](/codes/nack/0x000c/): A gateway term: the request named an endpoint, one of a gateway's ports or universes, that it does not have. A fixture on a DMX cable sends this only through a gateway; check the port number asked for.
- [`0x000D` NR_INVALID_ENDPOINT_MODE](/codes/nack/0x000d/): A gateway term: the port is in a mode that does not allow the request, such as an input where the request needs an output. Change the port's direction or mode on the gateway first.
- [`0x000E` NR_UNKNOWN_UID](/codes/nack/0x000e/): The device does not know the UID the request asked about, usually a gateway or proxy asked about a unit it has not discovered. Run discovery through it again.
- [`0x000F` NR_UNKNOWN_SCOPE](/codes/nack/0x000f/): An RDMnet term: the device is not in the scope the request named. It matters only on an RDMnet network, never on a DMX cable.
- [`0x0010` NR_INVALID_STATIC_CONFIG_TYPE](/codes/nack/0x0010/): An RDMnet term: the device does not take the configuration type in the request. It matters only on an RDMnet network, never on a DMX cable.
- [`0x0011` NR_INVALID_IPv4_ADDRESS](/codes/nack/0x0011/): Network setup: the device would not take the IPv4 address in the request, a broadcast or reserved address, say. Check the address, mask and gateway together.
- [`0x0012` NR_INVALID_IPv6_ADDRESS](/codes/nack/0x0012/): Network setup: the device would not take the IPv6 address in the request. Check the address and prefix together.
- [`0x0013` NR_INVALID_PORT](/codes/nack/0x0013/): Network setup: the device would not take the port number in the request. Port 0, and ports the device keeps for itself, are the usual cause.
- [`0x0014` NR_DEVICE_ABSENT](/codes/nack/0x0014/): The sub-device or sensor is in the unit's numbering but is not there now: a module unplugged, a sensor board missing or not detected. Worth chasing at the bench, since it can be a loose connector inside the unit.
- [`0x0015` NR_SENSOR_OUT_OF_RANGE](/codes/nack/0x0015/): The request named a sensor past the unit's sensor count. If the count the unit reports says that sensor should be there, it contradicts itself.
- [`0x0016` NR_SENSOR_FAULT](/codes/nack/0x0016/): The unit says the sensor itself is faulty and gave no reading. A real lead at the bench: look at the sensor, its wiring and its connector before anything the sensor watches.
- [`0x0017` NR_PACKING_NOT_SUPPORTED](/codes/nack/0x0017/): The request bundled several values into one packed message, which this parameter cannot carry. The controller's concern rather than the fixture's: ask one at a time.
- [`0x0018` NR_ERROR_IN_PACKED_LIST_TRANSACTION](/codes/nack/0x0018/): Of several values sent in one packed message, at least one failed. The rest may or may not have taken, so read each back on its own.
- [`0x0019` NR_PROXY_DROP](/codes/nack/0x0019/): A proxy passed the request on and lost the unit's reply. The unit may have acted on it: read the setting back directly before assuming either way.
- [`0x0020` NR_ALL_CALL_SET_FAIL](/codes/nack/0x0020/): A change sent to every sub-device at once failed on at least one of them. Read each sub-device back to find which; the others may have changed.