Codes

Status messages

Every standard RDM status message ID by number, a fixture's report of a fault or warning in itself, with what each means at the bench.

Status IDs
34
Numbered in
E1.20, Appendix B
Version
0.12.0
Runs on
macOS 15 Sequoia or later, Apple silicon or Intel
Needs
An Enttec DMX USB Pro with its DMX/RDM firmware (major version 2), or, on a rig, an Art-Net 4 node with RDM on at its ports
Price
Free

A fixture reports its own faults and warnings as status messages, each with an ID. The standard ones are numbered in E1.20’s Appendix B; a maker may add its own, which only the fixture can describe. RDMBench’s report and monitor show them in words. Here is every standard ID by number, with what it means at the bench, in RDMBench’s words rather than the standard’s.

  • 0x0001 STS_CAL_FAIL: A moving part, named in the message by its slot (pan, tilt, a wheel), did not finish calibrating at power-up or reset. Look at that part’s motor, belt and home sensor, and anything blocking its travel, and watch it reset.
  • 0x0002 STS_SENS_NOT_FOUND: The unit could not find the home or position sensor for the part the message names. Usually the sensor, its cable or connector, or a magnet or flag that has moved; less often the part never reached the sensor at all.
  • 0x0003 STS_SENS_ALWAYS_ON: The position sensor for the part the message names reads as triggered all the time: shorted, stuck, or with something parked in front of it. The unit cannot find home while it does.
  • 0x0004 STS_FEEDBACK_ERROR: By its own position feedback, the part the message names is not where the unit sent it. Lost steps, a slipping belt, a stiff bearing, or a feedback sensor that cannot be trusted.
  • 0x0005 STS_INDEX_ERROR: The part the message names lost its reference position, such as a wheel that skipped. A reset may clear it; if it comes back, look at the index sensor and anything that lets the part slip.
  • 0x0011 STS_LAMP_DOUSED: The lamp has been turned off, by a controller, the panel or the unit itself. Not a fault by itself; if no one turned it off, look at the unit’s lamp settings (off on DMX loss, say) and its temperatures.
  • 0x0012 STS_LAMP_STRIKE: The unit tried to light the lamp and it did not come on. A lamp at the end of its life, the igniter or ballast, or a lamp still too hot to restrike.
  • 0x0013 STS_LAMP_ACCESS_OPEN: The unit reads the lamp cover or its interlock switch as open and will not run the lamp. Check that the cover is shut and the switch makes contact.
  • 0x0014 STS_LAMP_ALWAYS_ON: The lamp is on when the unit expects it off: a relay or ballast stuck on. Treat it as a safety problem until it is found.
  • 0x0021 STS_OVERTEMP: A sensor, numbered in the message, reads above its limit, and the message carries the temperature. Fans, filters and dust first; then the sensor itself, if the reading does not match how warm the unit really is.
  • 0x0022 STS_UNDERTEMP: A sensor, numbered in the message, reads below its limit, and the message carries the temperature. A unit fresh from a cold truck may say this until it warms; in a warm room, suspect the sensor.
  • 0x0023 STS_SENS_OUT_RANGE: A sensor, numbered in the message, reads outside what it can measure. More often a sensor open or shorted, or its connector off, than a real extreme.
  • 0x0031 STS_OVERVOLTAGE_PHASE: The supply on the phase the message numbers is above the unit’s limit, and the message carries the voltage. Check the supply before the unit: a wrong voltage setting, or a lost neutral on a three-phase feed.
  • 0x0032 STS_UNDERVOLTAGE_PHASE: The supply on the phase the message numbers is below the unit’s limit, and the message carries the voltage. A long or thin cable, a weak generator, or a voltage setting wrong for the supply.
  • 0x0033 STS_OVERCURRENT: The current on the phase the message numbers is over the unit’s limit, and the message carries the current. A shorted load or output stage, or more load than the circuit is rated for.
  • 0x0034 STS_UNDERCURRENT: The current on the phase the message numbers is below what the unit expects, and the message carries the current. On a dimmer, a lamp out or a load not connected.
  • 0x0035 STS_PHASE: The phase angle of the supply phase the message numbers, in degrees. A reading, not a fault.
  • 0x0036 STS_PHASE_ERROR: Something is wrong with the supply phase the message numbers: missing, or out of order on a multi-phase feed. Check the feed before the unit.
  • 0x0037 STS_AMPS: A current, carried in the message. A reading, not a fault.
  • 0x0038 STS_VOLTS: A voltage, carried in the message. A reading, not a fault.
  • 0x0041 STS_DIMSLOT_OCCUPIED: From a dimmer rack: that position holds no dimmer the rack can drive, empty or filled with something else. Check what is seated there against the rack’s own setup.
  • 0x0042 STS_BREAKER_TRIP: A circuit breaker in the unit or rack has tripped. Find out why before resetting it: a shorted lamp or cable on that circuit, or more load than it carries.
  • 0x0043 STS_WATTS: A power, carried in the message. A reading, not a fault.
  • 0x0044 STS_DIM_FAILURE: A dimmer has failed. Look at its output stage and its fuse, or swap the module to see whether the fault follows it.
  • 0x0045 STS_DIM_PANIC: The rack or dimmer is in panic mode, running fixed levels whatever DMX says, usually turned on by a panic or emergency input. Check that input and the rack’s panel before chasing DMX.
  • 0x0046 STS_LOAD_FAILURE: The unit sees no load, or a failed one, on an output: a lamp burned out, or a cable or connector open between the unit and the lamp.
  • 0x0050 STS_READY: The part the message names is ready. A reading, not a fault: it usually follows a not-ready message once that part has warmed up or calibrated.
  • 0x0051 STS_NOT_READY: The part the message names is not ready yet: warming, filling or calibrating. Wait for its ready message; if it never comes, the part is stuck there.
  • 0x0052 STS_LOW_FLUID: The part the message names is low on fluid, typically a hazer’s or smoke machine’s supply. Refill it; if the message stays, check the level sensor.
  • 0x0060 STS_EEPROM_ERROR: The unit’s settings memory failed a check. Settings may not survive a power cycle, or may have gone back to defaults. A factory reset or a firmware reload sometimes clears it; if it returns, it is the board.
  • 0x0061 STS_RAM_ERROR: The unit’s working memory failed a check. A board fault: note the firmware version and whether it comes back after a power cycle.
  • 0x0062 STS_FPGA_ERROR: A programmable chip in the unit did not load its configuration. A firmware reload may cure it; if not, it is the board.
  • 0x0070 STS_PROXY_BROADCAST_DROPPED: A proxy could not pass a broadcast, a request to every unit, on to the units behind it, and the message names the parameter. Those units may not have had it: send it again, or address them one at a time.
  • 0x0071 STS_ASC_RX_OK: The unit received DMX with an alternate start code and took it, and the message carries the code. A reading, not a fault, from units that report what arrives on their DMX input.