Status messages
Every standard RDM status message ID by number, a fixture's report of a fault or warning in itself, with what each means at the bench.
A fixture reports its own faults and warnings as status messages, each with an ID. The standard ones are numbered in E1.20’s Appendix B; a maker may add its own, which only the fixture can describe. RDMBench’s report and monitor show them in words. Here is every standard ID by number, with what it means at the bench, in RDMBench’s words rather than the standard’s.
0x0001STS_CAL_FAIL: A moving part, named in the message by its slot (pan, tilt, a wheel), did not finish calibrating at power-up or reset. Look at that part’s motor, belt and home sensor, and anything blocking its travel, and watch it reset.0x0002STS_SENS_NOT_FOUND: The unit could not find the home or position sensor for the part the message names. Usually the sensor, its cable or connector, or a magnet or flag that has moved; less often the part never reached the sensor at all.0x0003STS_SENS_ALWAYS_ON: The position sensor for the part the message names reads as triggered all the time: shorted, stuck, or with something parked in front of it. The unit cannot find home while it does.0x0004STS_FEEDBACK_ERROR: By its own position feedback, the part the message names is not where the unit sent it. Lost steps, a slipping belt, a stiff bearing, or a feedback sensor that cannot be trusted.0x0005STS_INDEX_ERROR: The part the message names lost its reference position, such as a wheel that skipped. A reset may clear it; if it comes back, look at the index sensor and anything that lets the part slip.0x0011STS_LAMP_DOUSED: The lamp has been turned off, by a controller, the panel or the unit itself. Not a fault by itself; if no one turned it off, look at the unit’s lamp settings (off on DMX loss, say) and its temperatures.0x0012STS_LAMP_STRIKE: The unit tried to light the lamp and it did not come on. A lamp at the end of its life, the igniter or ballast, or a lamp still too hot to restrike.0x0013STS_LAMP_ACCESS_OPEN: The unit reads the lamp cover or its interlock switch as open and will not run the lamp. Check that the cover is shut and the switch makes contact.0x0014STS_LAMP_ALWAYS_ON: The lamp is on when the unit expects it off: a relay or ballast stuck on. Treat it as a safety problem until it is found.0x0021STS_OVERTEMP: A sensor, numbered in the message, reads above its limit, and the message carries the temperature. Fans, filters and dust first; then the sensor itself, if the reading does not match how warm the unit really is.0x0022STS_UNDERTEMP: A sensor, numbered in the message, reads below its limit, and the message carries the temperature. A unit fresh from a cold truck may say this until it warms; in a warm room, suspect the sensor.0x0023STS_SENS_OUT_RANGE: A sensor, numbered in the message, reads outside what it can measure. More often a sensor open or shorted, or its connector off, than a real extreme.0x0031STS_OVERVOLTAGE_PHASE: The supply on the phase the message numbers is above the unit’s limit, and the message carries the voltage. Check the supply before the unit: a wrong voltage setting, or a lost neutral on a three-phase feed.0x0032STS_UNDERVOLTAGE_PHASE: The supply on the phase the message numbers is below the unit’s limit, and the message carries the voltage. A long or thin cable, a weak generator, or a voltage setting wrong for the supply.0x0033STS_OVERCURRENT: The current on the phase the message numbers is over the unit’s limit, and the message carries the current. A shorted load or output stage, or more load than the circuit is rated for.0x0034STS_UNDERCURRENT: The current on the phase the message numbers is below what the unit expects, and the message carries the current. On a dimmer, a lamp out or a load not connected.0x0035STS_PHASE: The phase angle of the supply phase the message numbers, in degrees. A reading, not a fault.0x0036STS_PHASE_ERROR: Something is wrong with the supply phase the message numbers: missing, or out of order on a multi-phase feed. Check the feed before the unit.0x0037STS_AMPS: A current, carried in the message. A reading, not a fault.0x0038STS_VOLTS: A voltage, carried in the message. A reading, not a fault.0x0041STS_DIMSLOT_OCCUPIED: From a dimmer rack: that position holds no dimmer the rack can drive, empty or filled with something else. Check what is seated there against the rack’s own setup.0x0042STS_BREAKER_TRIP: A circuit breaker in the unit or rack has tripped. Find out why before resetting it: a shorted lamp or cable on that circuit, or more load than it carries.0x0043STS_WATTS: A power, carried in the message. A reading, not a fault.0x0044STS_DIM_FAILURE: A dimmer has failed. Look at its output stage and its fuse, or swap the module to see whether the fault follows it.0x0045STS_DIM_PANIC: The rack or dimmer is in panic mode, running fixed levels whatever DMX says, usually turned on by a panic or emergency input. Check that input and the rack’s panel before chasing DMX.0x0046STS_LOAD_FAILURE: The unit sees no load, or a failed one, on an output: a lamp burned out, or a cable or connector open between the unit and the lamp.0x0050STS_READY: The part the message names is ready. A reading, not a fault: it usually follows a not-ready message once that part has warmed up or calibrated.0x0051STS_NOT_READY: The part the message names is not ready yet: warming, filling or calibrating. Wait for its ready message; if it never comes, the part is stuck there.0x0052STS_LOW_FLUID: The part the message names is low on fluid, typically a hazer’s or smoke machine’s supply. Refill it; if the message stays, check the level sensor.0x0060STS_EEPROM_ERROR: The unit’s settings memory failed a check. Settings may not survive a power cycle, or may have gone back to defaults. A factory reset or a firmware reload sometimes clears it; if it returns, it is the board.0x0061STS_RAM_ERROR: The unit’s working memory failed a check. A board fault: note the firmware version and whether it comes back after a power cycle.0x0062STS_FPGA_ERROR: A programmable chip in the unit did not load its configuration. A firmware reload may cure it; if not, it is the board.0x0070STS_PROXY_BROADCAST_DROPPED: A proxy could not pass a broadcast, a request to every unit, on to the units behind it, and the message names the parameter. Those units may not have had it: send it again, or address them one at a time.0x0071STS_ASC_RX_OK: The unit received DMX with an alternate start code and took it, and the message carries the code. A reading, not a fault, from units that report what arrives on their DMX input.