Fixtures / Martin Professional A/S

Martin Professional A/S MAC AURA

The Martin Professional A/S MAC AURA as it describes itself over RDM: 2 personalities, 7 sensors and 33 parameters, with 1 known quirk, each sourced.

Manufacturer ID
0x4D50
Model ID
0x0003
Category
Fixture (moving yoke)
Firmware
MAC AURA 1.2.0
Version
0.12.0
Runs on
macOS 15 Sequoia or later, Apple silicon or Intel
Needs
An Enttec DMX USB Pro with its DMX/RDM firmware (major version 2), or, on a rig, an Art-Net 4 node with RDM on at its ports
Price
Free

What the Martin Professional A/S MAC AURA says about itself over RDM, captured from one unit with RDMBench, and what the model is known to get wrong. It is models/martin-professional/mac-aura.json in rdmbench-pids, the public fixture library a bench downloads with its PID tables.

A profile is true of the firmware it was captured from: personalities and sensors change between versions. On the bench, the fixture’s own answers always win.

Source: Captured by RDMBench 0.8.0 from the fixture’s own DEVICE_INFO / DMX_PERSONALITY_DESCRIPTION / SENSOR_DEFINITION: MAC AURA, software MAC AURA 1.2.0, 2026-10-31

Known quirks

DEVICE_INFO’s footprint is stuck

DEVICE_INFO reports the same DMX footprint in every personality, while each personality describes its own. Where the two disagree it is the model, not a unit caught mid-mode-change, and RDMBench places its channels by the smaller of the two.

Source: Observed on the RDMBench bench on 2026-10-31, one unit (4D50:0113201E) on firmware MAC AURA 1.2.0, through an Enttec DMX USB Pro: in personality 2, Extended, entered both by SET DMX_PERSONALITY and by its own self-test, DEVICE_INFO’s DMX footprint read 0x000E (14), Standard’s, while DMX_PERSONALITY_DESCRIPTION gave 25 (E1.20 §10.5.1 makes DEVICE_INFO’s footprint the current personality’s). The 25 agrees with the manual (UM_MACAura_EN_B, p. 11: Extended uses 25 DMX channels), so the 14 is the stale number. Not yet confirmed by a DMX frame on channels 15-25.

DMX personalities

PersonalityNameFootprintFrom the library
1Standard14 channelsNothing
2Extended25 channelsNothing

Sensors

SensorNameTypeRangeNormalRecords
0PCB temperaturetemperature-10 to 80 °C10 to 70 °CA recorded value
1LED beam temperaturetemperature-10 to 80 °C10 to 70 °CA recorded value
2LED aura temperaturetemperature-10 to 80 °C10 to 70 °CA recorded value
3PCB voltagevoltage0 to 30 V20 to 30 VA recorded value
4LED voltagevoltage0 to 90 V80 to 90 VA recorded value
5Device Power Cyclescounter-32768 to 32767-32768 to 32767Nothing
6Device Lifetime Hourscounter-32768 to 32767-32768 to 32767Nothing

Parameters

It lists 33 parameters in SUPPORTED_PARAMETERS.

Standard (E1.20 and E1.37): 0x0020, 0x0030, 0x0031, 0x0032, 0x0050, 0x0051, 0x0080, 0x0081, 0x0082, 0x0090, 0x00E0, 0x00E1, 0x0121, 0x0200, 0x0201, 0x0400, 0x0405, 0x0501, 0x0600, 0x0601, 0x0602, 0x1001, 0x1020, 0x1021

Martin Professional A/S’s own:

PIDName
0x8001DMX_RESET
0x8308DISPLAY_ERRORS_ENABLE
0x8310DIMMER_CURVE
0x8312DISPLAY_AUTO_OFF
0x8400PAN_TILT_SPEED
0x8604FAN_MODE
0x8700SERIAL_NUMBER
0x8703GENERATE_RANDOM_UID
0x8704RANDOM_UID_ENABLE

Names are from the Martin Professional A/S table. A fixture that describes a parameter itself wins over the table.