Fine in one mode, not in others
Some faults only show in one personality (mode): a status message that only appears in the extended mode, a channel that does nothing in the 16-bit mode, a sensor that only moves under load in one of them. A mode sweep finds them. It runs the same check in each mode you pick, shows the modes side by side, and then puts the unit back in its own mode and at its own address.
What differs between the columns is the finding. A fault in one mode only is that mode or its firmware, not the cable or the lamp, and saves readdressing a rig to chase it.
In the app
Select the fixture and choose Fixture → Sweep Modes… (macOS) / Fixture → Measure → Sweep modes… (Windows, Linux), or right-click the unit in the sidebar (macOS) / the fixture list (Windows, Linux). Pick the check:
- Report: the report in each mode, and nothing else.
- Under Load: the report, then the fixture lit and its sensors read in each mode, as a load test does. The fixture goes bright and hot in each mode. Each mode is held for 30 seconds unless you choose otherwise. Each mode starts warmer than the one before it, so a temperature that only differs in the later modes may be the earlier mode’s heat, not the mode itself. Sweep that mode on its own, from cold, to be sure.
- Walk by Eye: the report, then each mode’s channels walked one at a time, as Walk Channels does. Mark each channel, then click Next Mode. End Sweep stops early.
Under Load and Walk by Eye light the fixture, so they are offered only on a connection that can send DMX: the widget, or a universe of an Art-Net rig that nothing else is driving (Send DMX says how a node is checked).
Then tick the modes to run. Every mode the unit lists is ticked to start, with its channel count. A mode whose channels would run past 512 at the unit’s address is skipped and nothing is sent, and the sheet (macOS) / dialog (Windows, Linux) says so before you start.
Sweep sets each mode and reads it back, takes the report again, and runs the check. Stop finishes the mode it is in. Either way, the unit goes back to the mode and address it was in before the results appear. If it can’t be put back, the results say so first, with the mode it was in. Set it back with Fixture → Change Address and Mode… (macOS) / Fixture → Change address and mode… (Windows, Linux) or from the unit’s menu.
A console patched to the unit sees the wrong mode while the sweep runs. The sweep is unavailable while levels are held with Send DMX, during a load test, during a channel walk and while the unit is being monitored. Each of those is placed by the unit’s mode.
Reading the results
One column per mode: its channel count, the report’s verdict and how many lines are above OK, and the check’s own result. The channel count is the one the mode describes. Where the unit reports a different number for itself in that mode, that number is shown under it, and the disagreement is one line under What differs with the modes it showed in (see Footprint disagrees with the mode). Under What differs is each line of the report, sensor or channel that showed in some modes and not the others, with the modes it showed in. A mode that was skipped, failed or not reached says why below.
The sweep is filed under the unit, and its repair sheet lists what differed. Loads and walks run inside a sweep are part of the sweep, not filed on their own.
If RDMBench quits during a sweep
The next launch lists the sweep under Interrupted Work, with the mode it left the unit in and the mode and address it came from. Click Put Back to set the unit back once its line is open. See Interrupted work.
From the command line
rdmbench-cli sweep runs the report in every mode of the first fixture
found, or of the UID given after it, and prints the modes side by side.
--mode 1 --mode 3 picks the modes. --check load lights the fixture
in each mode for --seconds (30 by default). --check walk walks each
mode’s channels at the keyboard. Ctrl-C stops after the mode it is in
and still puts the unit back. rdmbench-cli recover lists a sweep a
killed run left behind, and restore puts its unit back.
From an AI assistant
An assistant connected to the bench can run a sweep with the report or the load check, never a walk. It asks you before changing anything, and puts the unit back before it answers. It is not offered on an Art-Net rig for now; run the sweep yourself there.