# Read a fixture's report

- **MCP resource:** rdmbench://help/report
- **Version:** 0.2.0
- **Runs on:** macOS 15 Sequoia or later, Apple silicon or Intel
- **Needs:** An Enttec DMX USB Pro with its DMX/RDM firmware (major version 2)
- **Price:** Free

The report is everything the fixture says about itself over RDM, in the
order a repair goes: who it is, whether anything is wrong, then the
detail behind that. Read the rating at the top and the **Device state**
section first. Most of the time the answer is in one of them.

## Taking a report

Select the fixture in the sidebar and open the **Report** tab. A report
is taken when the fixture is first found. Take a fresh one after
changing something with **Fixture → Take Snapshot** (⌘S) *(macOS)*.
**Fixture → Scan All Fixtures** takes one of every unit on the line.

Each report is kept in the bench's captures folder, so the next visit
can be compared with this one (**Fixture → Compare with Previous
Visit…**).

## The header

The fixture's name, its label and software version, its counters
(device hours, lamp hours and strikes, power cycles) and one rating for
the whole unit: **OK**, **WARNING** or **ERROR**. The rating is the
worst of the fixture's own status messages and its sensors measured
against their limits.

When the brand reads *brand by UID*, the fixture did not give its
manufacturer's name. The name shown is the one ESTA registered for the
first part of its UID.

## Came in for

Under the header, **Came in for** is what the customer says is wrong:
wrong colors, flickers, doesn't follow the desk, won't home or moves
wrong, overheats or shuts off, dim or no output, or answers on the wrong
channels. Choose one or more from its menu. The report then opens with a
**Came in for** section that lists, for each complaint, the lines
further down that explain it, with where each one is. Nothing is hidden:
every line in it is also in its own section.

When nothing the fixture reports explains a complaint, the section says
so, and says what RDM cannot see. For flicker that is usually the
cable, the termination or a ground loop, which is the cue to stop
looking at the fixture and look at the line (see
[Line faults](/help/line-faults/)).

The complaint is kept with the unit as a repair note against the
report on screen, so its next visit opens with it too. Choose
**Clear Complaint** from the menu once it no longer applies.

From the command line, `rdmbench-cli snapshot --symptom flickers` reads
a report for that complaint and files it, and `--symptom` can be given
more than once. `rdmbench-cli note 4D50:0A1B2C3D --symptom dim` sets the complaint for that unit
without taking a report, and `--clear-symptoms` clears it.

## Device state

Things that make a working fixture look dead or broken: a shipping
lock, a power state other than normal, a preset playing back, or the
fixture identifying right now. These sit near the top because they
explain a symptom rather than record one. Identify is rated OK, since
you may have just turned it on.

What each of these means, and what to do about it, is in
[A working fixture that looks broken](/help/looks-broken/). A
count of bad frames on the fixture's DMX input is listed here too, and
points at the cable before the fixture (see
[Corrupt frames: check the line](/help/line-faults/)).

Notes from discovery also sit here. A proxy (a splitter or gateway)
may have answered for the fixture, so what follows may be the proxy's
copy of its state. The unit may itself be a proxy, with the fixtures
behind it listed as their own units, or one port of a unit with
several.

Some models are known to report something wrong. Where the bench has
that model's profile, this section reads the value the right way round
and says what the model gets wrong, who observed it and how. The stored
reading is never changed.

## Sensors

Every sensor the fixture reports: temperatures, voltages, fan speeds.
Each shows its value, the normal range and full range the fixture
declares, and the lowest and highest it has seen. A reading outside its
normal range is flagged.

Fixtures report temperatures in °C. To see them in °F, open
Settings (⌘,) *(macOS)* and choose **Temperatures**
under *Display*. A saved report keeps what the fixture reported, so it
shows in whichever unit is chosen when it is opened.

## DMX configuration

The DMX start address, the personality (the fixture's word for its
mode) and how many channels it takes. The **Channels** list is what each
channel does in this personality, from the fixture's own slot table.

A wrong address or the wrong personality is often the whole fault: a
fixture showing the wrong colors with no error code is usually patched
on the desk in a different mode from the one it is in. Compare the
channel list with the desk's patch (see
[Wrong colors: check the patch](/help/address-mode/)). Where
the bench has GDTF files, this section also says what a desk calls this mode (see
[Find a fixture's desk mode](/help/desk-mode/)).

## Status messages

The fixture's own faults and warnings, in words: the standard's for
standard messages, and the fixture's own description for the ones its
maker defined.

## Changed at the device

Settings changed at the fixture's front panel since the line last asked.
In practice, this is a record of what the last person to touch the unit
did.

## Further down

- **Sub-devices**: modules inside the unit that answer for themselves,
  each with its own rating. A module with status reporting switched
  off, or set to report errors only, is said under it: its faults, or
  its warnings, are missing from the status messages, which is not
  evidence that it is healthy.
- **Self-test**: the tests the fixture can run on itself, if any, and
  any it reports as running, failed or finished with a result. A
  failed test is the fixture's own verdict on itself.
- **Device details**: serial number, product category and details,
  the maker's web addresses, and other identifying details.
- **Parameters**: every parameter the fixture supports, standard and
  manufacturer-specific, for digging deeper.
- **Text that is not printable ASCII**: shown only when the fixture sent
  stray bytes in its text, with what came off the wire. That is a
  firmware fault, not a fault in the unit.
- **Problems during read**: anything the fixture did not answer. A
  required parameter it ignores is listed here.

## From the command line

`rdmbench-cli snapshot` prints the same report for the first fixture
found, or for the UID given. `--json` prints it as the document the app
reads, and `--sim` runs it against the simulator with no hardware.

To light the fixture while you read it, see
[Send DMX](/help/send-dmx/).